The cookie settings on this website are adjusted to allow all cookies so that you have the very best experience. If you continue without changing your cookie settings, we'll assume that you are happy to receive all cookies on our website. However, if you would like to, you can change your settings at any time using the Change cookie settings link in the Special menu.        

VN2000 Hot Tap Insertion Style Vortex Flow Meter

VN2000 Hot Tap Insertion Style Vortex Flow Meter

VN2000 Hot tap Insertion Style Vortex Flow Meter

The VN2000 Hot Tap Insertion Vortex Flow Meter measures the volumetric flow, mass flow rate or BTU/energy of steam, gas or liquids over a large flow range. The meter is a heavy duty design engineered to stand up to the most abusive environments inside and outside the pipe.

 

 

Technical data

 

Medium

Steam/gas

Connections

1 1/2" NPT, ASME/ANSI 150, 300 flanged

Pipe sizes

DN50 - DN1200 (2" - 48")

Flow range*

Steam: 26 - 2282271 kg/m³

 

Gas/air: 0,5 - 187593 kg/m³

Pressure range

Steam: 0,4 - 27 bar

 

Gas/air: 0 - 69 bar

Accuracy

± 1 % of reading

Repeatability

± 0,25 % of reading

Output

1 x 4-20 mA, 10-36 V max. load, 24 bit resolution

 

Adjustments of 4 mA and 20 mA signal from the keypad and reset of anomalies found between the meter and the monitoring device

*Depending on pipe size and pressure/density

 

Downloads

 

 Specification Datasheet

 User Manual